E32-T16 type: special beam type; region detection,
Specialty: regional width 10mm long distance,
Shape / detection distance (mm): 3700; 2800; 1850 (740),
Bending radius (mm): R25.
Standard test object (minimum test object) (mm) 1: (0.6) 4,
Fiber element for meeting diversified needsSize: 48 x 96mm.
Type: power AC/DC24V with E5CC-CX3ASM-004 User's Manual.
Shell color: black.
Control output 1: position ratio with relay output
E5CC-CX3ASM-004
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-485 E5CC-CX3ASM-004 User's Manual.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors E5CC-CX3ASM-004 User's Manual.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Appearance: R-shaped.
Sensing method: Through beam type (with slot).
Connecting method: Connector model (4 poles).
Sensing distance: 5 mm (slot width).
Operating mode: Dark-ON/Light-ON (2 outputs).
Indicator mode: Incident light.
Model: PNP output.
Built-in connector enables,
downsizing and easier connection.
Protective circuit for safe operation.
A built-in connector minimizes the shape and dimensional,
requirements.
Two outputs: light-ON and dark-ON. E5CC-CX3ASM-004 Manual.
Complete lineup including seven different shapes.
Safer operation with built-in power supply reverse polarity,
protection.
Output overcurrent protection with a thermal shutdown,
circuit (patent pending).
The indicator can be seen from many directions to enable,
installation in more locations E5CC-CX3ASM-004 Manual.
Connector with lock that mates with commercially available,
connectors.