Sensing method: Distance-settable(BGS Models).
Connection method: Connector(M8, 4 pins).
Response time: 0.5 ms.
Sensing distance: 125 to 40 mm (Min. distance set),
25 to 300 mm (Max. distance set) .
Model: PNP output .
Compact and Reliable,
Laser Photoelectric Sensor.
Safety and reliability with laser class 1 (JIS and IEC) E5CC-CX2DSM-800 User's Manual.
Product lineup includes models with distance setting without,
influence of color
E5CC-CX2DSM-800
Maximum ambient operating temperature of 55°C and water,
proof construction in E3Z class.
E32-T12F type: resistant to environmental type; resistant to drugs,
Specialty: Teflon coating for long distance,
Shape / detection distance (mm): 4000; 3000; 2000 (800),
Bending radius (mm): R40 E5CC-CX2DSM-800 User's Manual.
Standard test object (minimum test object) (mm) 1: 4 (0.1),
Fiber element for meeting diversified needsSize: 1/8DIN 48 × 96 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Temperature Input Type.
Control method: Valve Control.
Number of alarms: 2.
Communica- tions function: RS-485.
Event input: None.
A position proportional control model for the E5EZ-PRR series E5CC-CX2DSM-800 User's Manual.
Depth of only 78 mm.
Various temperature inputs (thermocouple, platinum resistance thermometer,
infrared temperature sensor, voltage inputs) and analog inputs (current, voltage),
Makes use of high-visibility LCD, with three lines of 4-digit display,
for simplicity.
and clarity.
3 lines of display to observe PV/ SV/ MV (valve open percentage),
clearly displaying the state of control (operations).
Event input enables multi-SP selection and run/ stop function.
Alarm delay function.
Communications function.
Able to choose closed/floating control. In floating control,
position proportional control can be performed without a potentiometer,
Equipped with a manual output function (equipped with an automatic/manual key),
CE marking and UL/CSA certification. Control output: linear current output.
Auxiliary output: -.
Heating wire break, SSR fault detection function: -.
Event input: -.
Communication: RS-485.
Terminal shape: main unit (no terminal unit).
Power supply voltage: AC100 ~ 240V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adappter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) E5CC-CX2DSM-800 Manual.
With auxiliary output (maximum 2 points), event input (maximum 1 points), tthe basic function is complete E5CC-CX2DSM-800 Manual.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).