Pressure range: Positive pressure; 0 to 100 kPa.
ON/OFF output: Open collector (two independent outputs).
Linear output: 1 to 5 V.
Model: PNP output.
Pressure Sensor with.
Easy-to-Read LED Display.
Pressure status can be checked at a glance from the,
digital display and bar display.
Measurement pressure prevents incorrect outputs due,
to momentary pressure changes E5AN-Q3HBL-N User's Manual
E5AN-Q3HBL-N
Perform automatic teaching simply by teaching pressure,
values for good and bad products.
Industry’s smallest models at just 28 × 28 × 29 mm.
Only in hysteresis mode. Appearance: Unshielded, M12.
Sensing distance: 8 mm.
Model: Operation mode, NC.
Proximity Sensor with a Long Screw Length.
Increased tightening strength E5AN-Q3HBL-N User's Manual. Cable protectors,
provided as a standard feature.
Increased indicator visibility.
A milled section for wrench grip on all models. Power supply voltage: 12 to 24 VDC.
Output configuration: Open-collector output.
Resolution (divisions): 256 (8-bit).
Connector for H8PS Cam Positioner: None.
General-purpose Absolute Encoder.
with External Diameter of 50 mm.
Absolute model.
External diameter of 50 mm E5AN-Q3HBL-N User's Manual.
Resolution: 256 (8-bit).
Lightweight construction using plastic body. Size: 96 × 96 mm.
Control type: 2-loop control.
Control mode: 2-loop standard control, Single-loop heating and cooling control,
Single-loop cascade control, Single-loop control with remote SP,
Single-loop proportional control.
Outputs(control/transfer): 2 points: Pulse voltage and Pulse voltage/current.
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 4; Serial communications, RS-485.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using moodels with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4 E5AN-Q3HBL-N Manual. 0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation) E5AN-Q3HBL-N Manual.
DeviceNet Communications.
Data setting and monitoring can be performed without special programming.