Protection tube diameter: screw pitch M6.
Wire length: 2m.
Core line type: K (CA).
Temperature sensing part of temperature controller.
In the application field of packaging molding machine is widely used,
Further strengthened the high cost models.
Easy to install / replace the structure.
With springs, you can use the active part (E52Z-CA1D-40) E5AN-HPRR201BF-FLK User's Manual. High performance price ratio standard type proximity sensor
E5AN-HPRR201BF-FLK
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC two-wire / connector type.
Polarity: there.
Shape: shield, M12.
Detection range: 3mm.
Action mode: NC. Size: 48 x 48mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 2 independent points E5AN-HPRR201BF-FLK User's Manual.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: 4 points.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points E5AN-HPRR201BF-FLK User's Manual.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately).
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual,, RUN/STOP, alarm), interactive display PV/SV E5AN-HPRR201BF-FLK Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5AN-HPRR201BF-FLK Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.