Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function E5AN-C3BT Basic Type.
Event entry point: 2.
Transfer output: -.
Communication: RS-485.
New program type
E5AN-C3BT
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms E5AN-C3BT Basic Type.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output E5AN-C3BT Basic Type.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Setting: simulation settings.
Indication mode: no indication.
Adjustment mode: proportional action (P).
Output: relay.
Input: thermocouple J.
The size of the DIN48 to achieve the simulation set, low cost.
The most small and realize the low cost of.
Proportional (P) action in the regulation mode.
And the reset function is added.
Through the installation of the adapter can be continuously close.
The installation of DIN guide rail and panel mounting can be carried out by means of insertion. Ontology: terminal type, analog input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -. E5AN-C3BT Manual.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further perfformance improvement E5AN-C3BT Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV state display function, convenient to view the thermostat