LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
DRT1-OD16T-1 OPERATION MANUAL ()
Product model: DRT1-OD16T-1
Name: Programmable Terminals
Brand: OMRON
Sort: OPERATION MANUAL
File language: English
Ratings: Standard load; 5 A at 125 VAC.
Cable: VCTF oil-resistant cable *1.
Actuator: Sealed pin plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models DRT1-OD16T-1 OPERATION MANUAL. )
Sealing characteristics that meet IEC IP67 degree of protection DRT1-OD16T-1
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers DRT1-OD16T-1 OPERATION MANUAL.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Actuator: Roller lever (resin lever, resin roller).
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 3NC (Slow-action).
Popular Safety Limit Switches DRT1-OD16T-1 OPERATION MANUAL.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Name: Safety I/O Terminals.
No. of I/O points: Safety inputs: 12, test outputs: 4.
Distributed Safety Terminals That.
Reduce Wiring.
Lineup incluudes four models to accommodate various,
I/O types and number of I/O points DRT1-OD16T-1 Manual.
Monitor the safety system from Standard Controllers,
across the network.
EN954-1 (Cat.4), ISO13849-1 (PLe),
and IEC 61508 SIL3 certification.
The DST1-XD0808SL-1 also supports logic operation,
functions for high-speed processing in applications,
requiring partial stopping of the safety system DRT1-OD16T-1 Manual.