Available on either 3.5” or 5.25” floppy disks.I/O bits: 5, 120 (Expan-sion Racks: 7).
Program capacity: 20K steps.
Data memory capacity: 64K words (DM: 32K words, EM: 32K words ×1 banks).Model: C500-CN131.
Cable length: 10 m.
Programming Console Connecting Cable.
For extension and connection of FIT of FIT CXONE-AL10D-V4 OPERATION MANUAL.
Product name: CS1 CPU Backplane.
Specifications: For both CS/C200H-series Units,
Units cannot be mounted; 5 slots
CXONE-AL10D-V4
Appli cable CPU Unit: CS1 CPU Unit.
Basic I/O Units: CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, Yes;
C200H Group-2 High density I/O Unit, Yes.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, Yes.
CPU Bus Units: CS-series CPU Bus Unit, Yes CXONE-AL10D-V4 OPERATION MANUAL.
Current consumption: 5V system, 0.11A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Inputs: 8I/O link input bits.
Outputs: 8I/O link input bits.8 pts, No-voltage contact. PNP.Model: CPM2C-16EDM. Units with inputs only.
1 MIL connector.
Inputs: 16 inputs.
Outputs: --- CXONE-AL10D-V4 OPERATION MANUAL.
Input type: 24 VDC.
Output type: --.C200H CPU 100/200-240VAC C200H-CPU02-E.C500-DA Special I/O Unit Analog Output C500-DA103.
Output: 4 pts.
Specification: -10~+10V.Output type: Relay.
Inputs points: 12 points.
Outputs points: 8 points.Model: C200H-OD217.
No. of points: 12 pts.
Specifications: 5 to 24 VDC. source type (PNP).Number of outputs: 8 pts.
Max. switch-ing capacity: 1.0 A at 24 V DC.
External connector: Terminal block.
Weight: 240 g max.Model: CPM2A-20CDT1-D. Power supply: DC power supply.
Output type: Transistor sourcing.
Inputs points: 12 points.
Outputs points: 8 points.Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications,
Units High-speed type.
Specifications:Communications Interface,
2 RS-422A/485 ports; Communications functions,
The following functions can be selected,
for each port with an CJ system:
Protocol macro, Host Link, NT Links (1:N mode),
Serial Gateway, No-protocol, Modbus-RTU Slave,
The following functions can be selected,
for each port with an NJ system: Protocol macro,
Serial Gateway, No-protocol, Modbus-RTU Slave.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.40A; 24V,--- CXONE-AL10D-V4 Manual.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485,, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol CXONE-AL10D-V4 Manual.