C200H Discrete I/O Data Access Console C200H-DAC01Model: C200HW-BI031.
No. of I/O slots: 3 slots.C500-IA I/O Unit AC Input 32 pts C500-IA122(3G2A5-IA122).
AC100-120V 10mA.Name: Analog I/O Slave Units.
Specifications: Analog outputs;
2 outputs.
Standards: CE, U, U1, C, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet CV500-CPU01-V1 Macro Reference.
Branching is easily made with CompoNet
CV500-CPU01-V1
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error CV500-CPU01-V1 Macro Reference. C500-CT/3G2A5-CT Special I/O Unit High-speed Counter 50 kcps 1 pts C500-CT001(3G2A5-CT001).Output method: Analog resolution: 1/6000.
Analog Outputs: 4.Model: CPM2C-32EDT1M. Units with 32 I/O points
2 MIL connectors.
Inputs: 16 inputs.
Outputs: 16 outputs.
Input type: 24 VDC.
Output type: sourcing transistor CV500-CPU01-V1 Macro Reference. C1000H-CP CPU 62 k words 1024 pts C1000H-CPU01-EV1.Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 2 loops,
heater burnout detection function;
Temperature sensor inputs: Thermocouple,
input (R, S, K, J, T, B, L);
Control outputs: Open collector,
NPN outputs (pulses).
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output. CPU Unit: CP1L-M CPU Units with 40 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, AC power supply; Output method, TTransistor output (sinking);
Inputs, 24; Output, 16 CV500-CPU01-V1 Manual.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CCP1L-L" has a standard-feature peripheral USB port CV500-CPU01-V1 Manual.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams.