Model: CPM2C-24EDT1M. Units with 24 I/O points
2 MIL connectors.
Inputs: 16 inputs.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: sourcing transistor.Model: C500-BC052(3G2A5-BC052).
5 slots(5 linkable slots).
Name: Clamp Terminal Blocks.
Specifications: Inputs/Outputs;
8 inputs/8 outputs ; PNP; -- CV500-BSC31 Macro Reference.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet
CV500-BSC31
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error CV500-BSC31 Macro Reference. Model: C200H-TM001.
Timing method: CR oscillator.
No. of timers: 4
Setting ranges: 0.1 to 1.0 s, 1 to 10 s, 10 to 60 s, 1 to 10 min
Operation: Controllable from PLC program. Usable as accumulating timer.
External adjustment: Via C4K-CN223 (2 m) connector to 20-Commonly used with other Communications Units CV500-BSC31 Macro Reference. OMRON PID Module C500-PID01(3G2A5-PID01-E)Product name: E@@S type CPU Units with 14 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 8; Outputs, 6;
Output type: Relay.
Program capacity: 2K steps.
memory Data capacity: 2K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.16A; 24 V,0.07A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Name: e-CON Connectors.
Specifications: Inputs/Outputs;
8 inputs /8 outputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost ccan be reduced CV500-BSC31 Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CV500-BSC31 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.