Name: MIL Connectors.
Specifications: Inputs;
16 inputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction CRT1-OD16S-1 REFERENCE MANUAL.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site
CRT1-OD16S-1
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Product name: Transistor Output Units.
Specifications: Output type, Sourcing;
I/O points, 8outputs;
Maximum switching capacity, 24VDC,
2AShort-circuit protection;
Commons, 4 points, 1 common;
External connection, Removable terminal block CRT1-OD16S-1 REFERENCE MANUAL.
No. of words allocated: 1 word.
Current consumption: 5V, 0.11A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices CRT1-OD16S-1 REFERENCE MANUAL.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput. No. of I/O slots: 5 slots.UM: 15.2K words.
DM: 6K words.
EM: 6K words.
Instruction processing time (basic instructions): 0.15 µ.s min.
No. of I/O points: 880 points.
Max. no.of con-necting Expansion I/O Racks: 2 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.Model : CV500-CN127.
BASIC unit for connecting the printer (1.5m)(Centronics).Output method: Transistor sinking.
Inputs: ---.
Outputs: 16.Name: Three-tier Screw Terminal Block.
Specifications: Inputs/Outputs;
8 inputs/8 outputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost caan be reduced CRT1-OD16S-1 Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CRT1-OD16S-1 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.