Product name: CJ2M CPU Units.
Specifications: I/O capacity/Mountable Units(Expansion Racks),
2, 560 points/40 Units(3 ExpansionRacks max. );Programcapacity,
60K steps;Data memorycapacity, 160K words,
(DM: 32K words, EM: 32K words ×4 banks);
LD nstruction execution time, 0. 04 μs;
EtherNet/IP function: --;
Option board slot: -- CPM2C-S110C OPERATION MANUAL.
Current consumption (A): 5V, 0
CPM2C-S110C 7(See note. );24V, --.
Standards: UC1, N, L, CE.
CJ2M for basic machine automation.
The CJ2M Series is ideal for packaging and general.
machine automation needs. Connectivity is assured.
thanks to the built-in USB port and the choice of.
Ethernet and RS-232C/422/485 interfaces on the CPU. Name: Two-tier Screw Terminal Block CPM2C-S110C OPERATION MANUAL.
Specifications: Inputs; 16 inputs; PNP.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site CPM2C-S110C OPERATION MANUAL.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: Position Control Module.
Model: C200H-NC112.
Control method: Open-loop, automatic trapezoid acceleration/deceleration.
Control output sig-nals: Pulse-train outputs.
Controlled axes: 1.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100, Pt50, Ni508.4.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.07A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spaace compared,
with previous systems CPM2C-S110C Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CPM2C-S110C Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.