Name: Temperature Sensor Module.
Model: C200H-TS102.
Temperature sensor: RTD (Pt 100 Ω.)(DIN/1989 JIS).
Input points: 4 points/Unit max. (1, 2, or 4 points can be selected).Name: e-CON Connectors.
Specifications: Outputs; 32 outputs; PNP;
Without Short-circuit and,
Disconnected Line Detection CP1L-M40DT1-D REFERENCE MANUAL.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet
CP1L-M40DT1-D
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error CP1L-M40DT1-D REFERENCE MANUAL. CPU Unit: CP1L-EL CPU Units with 20 Points.
Specifications: CPU type, Memory capacity: 5K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Transistor output(sourcing);
Inputs, 12; Output, 8 CP1L-M40DT1-D REFERENCE MANUAL.
Standards: CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. Name: Heat/Cool Temperature Control Module.
Model: C200H-TV103.
Sensor: Platinum resistance thermometer: JPt100, Pt100.
Control output: Current output(transistor output used for cooling outputs).Model: CPM2C-TS101. 2 inputs for temperature resistance thermometers Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications,
Units High-speed type.
Specifications:Communications Interface,
1 RS-232C port and 1 RS-422A/485 port;
Communications functions,
The following functions can be selected,
for each port with an CJ system:
Protocol macro, Host Link, NT Links (1:N mode),
Serial Gateway, No-protocol, Modbus-RTU Slave,
The following functions can be selected,
for each port with an NJ system: Protocol macro,
Serial Gateway, No-protocol, Modbus-RTU Slave.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.36A; 24V,,-- CP1L-M40DT1-D Manual.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485,, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol CP1L-M40DT1-D Manual.