LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
CJ2M-CPU15 OPERATION MANUAL ()
Product model: CJ2M-CPU15
Name: PLC
Brand: OMRON
Sort: OPERATION MANUAL
File language: English
Unit type: CJ1 Basic I/O Units.
Product name: DC Input/Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 32 inputs, 32 outputs;
Input voltage,Input current, 24VDC, 4.1mA,
12 to 24VDC, 0.3A;
Commons, 16 points, 1 common;
External connection, Fujitsu connector.
No CJ2M-CPU15 OPERATION MANUAL. of words allocated: 4 words.
Current consumption: 5V, 0.14A; 24V, -- CJ2M-CPU15
Standards: UC1, N, CE.
A Wide Range of Basic Mixed,
I/O Units for Different Applications,
and Wiring Methods.
One Mixed I/O Unit has connectors for,
both inputs and outputs.
Use Mixed I/O Units to easily ,
build space-saving systems.
Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 8 outputs;
Signal range selection:
Set separately for each output CJ2M-CPU15 OPERATION MANUAL.
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V;
1/4,000 (Settable to 1/8,000) *2.
Conversion period: 1 ms/point,
(Settable to 250 μs/point)*2.
Accuracy at ambient temperature of 25°C:
±0.3% of F.S.
External connection: Removable terminal block.
External power supply: 24 VDC +10% -15%, 140mA max CJ2M-CPU15 OPERATION MANUAL.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.14A; 24V, 0.14*3.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals. Name: e-CON Connectors.
Specifications: Outputs; 16 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced CJ2M-CPU15 Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CJ2M-CPU15 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.
Related products
OMRON
Programmable Controllers
CJ2M-CPU33
OMRON Programmable Controllers CJ2M-CPU33
Product name: CJ2M Built-inEtherNet/IP
OMRON
Programmable Controllers
CJ2M-CPU14
OMRON Programmable Controllers CJ2M-CPU14
Product name: CJ2M CPU Units. Specific
OMRON
Programmable Controllers
CJ2M-CPU12
OMRON Programmable Controllers CJ2M-CPU12
Product name: CJ2M CPU Units. Specific
OMRON
Programmable Controllers
CJ2M-CPU32
OMRON Programmable Controllers CJ2M-CPU32
Product name: CJ2M Built-inEtherNet/IP