Model : CV2000-CPU01-EV1.
SFC / Ladder 2, 048 (with RAM62K words, the top internal link).Product name: CS1 Expansion Backplanes.
Specifications: For CS-series,
Unit only Note: C200H series,
Units cannot be mounted; 10 slots.
Mountable configuration units:
Basic I/O Units, CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, No;
C200H Group-2 High density I/O Unit, No CJ1W-SCU21-V1 OPERATION MANUAL
CJ1W-SCU21-V1
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, No.
CPU Bus Units: CS-series CPU Bus Unit, Yes.
Current consumption: 5V system, 0.23A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control CJ1W-SCU21-V1 OPERATION MANUAL. CV500-VP CPU Bus Unit Personal Computer Unit Main Mem CV500-VP227.
8-MB memory; w/floating-point processor.Unit type: CS1 Special I/O Units.
Name: High speed Counter Units.
Specifications: Countable channels,
2; Encoder A and B inputs,
pulse input Z signals, Open collector,
Input voltage: 5VDC,12VDC, or 24VDC,
(only 1 axis for 5 V or 12 V input),
RS-422 line driver;
Max. counting rate, 50kHz, 500kHz CJ1W-SCU21-V1 OPERATION MANUAL.
No. of unit numbers allocated: 4.
Current consumption: 5V, 0.36A; 26V, --.
Standards: UC, N, L, CE.
High-Speed, Flexible Control With A,
Wide Array of Features.
Equipped with 2 or 4 Counters and counts,
over a maximum binary range of 32-bits.
Accepting input pulse frequencies of up,
to 500 kHz allows precise control of fast motions.
The Unit is equipped with 4 Digital Inputs,
4 Digital Outputs and 28 Soft Outputs.
A maximum response time of 0.5 ms guarantees,
high-speed closed loop control of applications. Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 8 inputs.
Signal range: 4 to 20 mA, 0 to 10 V,
0 to 5 V, 1 to 5 V.
Conversion speed (resolution):
250ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacee compared,
with previous systems CJ1W-SCU21-V1 Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CJ1W-SCU21-V1 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.