Name: Compact Connectors.
Specifications: Outputs; 2 outputs; PNP.
Bit slave of smallest class in industry,
Innovation in wiring for any type of machinery.
Available in 2 types: 2-point Bit Slave Unit,
and 4-point Bit Slave Unit.
Compact size for installation in limited space.
Save space and wiring since bit slave can be,
installed near I/O devices CJ1W-ETN21 OPERATION MANUAL.
Industry first bit slave connectable with round,
cables which can be easily purchased at a lower price
CJ1W-ETN21
Connectable with flat cables, too for easy wiring.
Cables are selectable depending on applications. CPU Unit: CP1L-L CPU Units with 20 Points.
Specifications: CPU type, Memory capacity: 5K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Transistor output (sinking);
Inputs, 12; Output, 8 CJ1W-ETN21 OPERATION MANUAL.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams CJ1W-ETN21 OPERATION MANUAL. C500-OD I/O Unit Transistor Output 64 pts C500-OD213(3G2A5-OD213).
DC24V 0.1A.Model: C200H-AD001.
Input points: 4.
Voltage input: 1 to 5V or 0 to 10 V.
Current input: 4 to 20 mA.C500-MD I/O Unit DC Input/Triac Output Unit (16 input/16 output pts) C500-MD211CN(3G2A5-MD211CN).
DC12~24V Input: 10mA、Output: 0.3A.Model : CV500-CN332.
Cable I / O connection.
30M cable length.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: R, S, K, J, T, L, B.
Conversion speed: 250 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 26V, --.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and sppace compared,
with previous systems CJ1W-ETN21 Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CJ1W-ETN21 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.