Product name: N@@S1- type CPU Units with 40 I/O Points.
Specifications: Power Supply, DC24V; Inputs, 24; Outputs, 16;
Output type: Transistor (sourcing).
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.31A; 24 V,0.02A.
Standards: CE CJ1M-CPU12-ETN HOST CONNECTION MANUAL.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient
CJ1M-CPU12-ETN
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Supply voltage: 100 to 120 or 200 to 240 VAC, 50/60 Hz
Output capacity: DC5V, 6 CJ1M-CPU12-ETN HOST CONNECTION MANUAL. 5ASpecification: Platinum resistance thermometer input (Pt100, JPt100),
manual operation,
ON/OFF or advanced PID control,
transistor (NPN) output, 4 loops.C500-OC I/O Unit Transistor Output 16 pts C500-OC221(3G2A5-OC221).
AC250/DC24V 2A.Power supply: DC power supply.
Output method: Transistor output source type.
Inputs points: 6 points.
Outputs points: 4 points.Name: SYSMAC LINK Module CJ1M-CPU12-ETN HOST CONNECTION MANUAL.
Model: C200HW-SLK23.
Communications method: N: N token bus.
Transmission method: Manchester code, base band.
Transmission path: Bus.
Weight: 400 g max.Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 4 loops;
Temperature sensor inputs: Thermocouple,
input (R, S, K, J, T, B, L);
Control outputs: Open collector NPN outputs (pulses).
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output. Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 8 inputs.
Signal range: 4 to 20 mA, 0 to 10 V,
0 to 5 V, 1 to 5 V.
Conversion speed (resolution):
250ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems CJ1M-CPU12-ETN Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CJ1M-CPU12-ETN Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.