Model: C500-BC051.
5 slots(3 linkable slots).
Model: CPM2C-20CDTC-D. CPU Unit: Units with 20 I/O points.
2 Fujitsu connectors.
Inputs: 12 inputs.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: sinking transistor.
Internal clock: --.Unit type: CS1 Special analog I/O Units.
Product name: Analog Output Units CJ1H-CPU67H HOST CONNECTION MANUAL.
Specifications: I/O points, 8 outputs;
Signal range selection,
Set separately for each input;
Signal range, 4 to 20 mA;
Resolution, 1/4000 ;
Conversion speed, 1 s/point
CJ1H-CPU67H
Externa connection, Removable erminal block.
Current consumption: 5V, 0.13A; 26V, 0.25A.
Standards: UC1, N, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data CJ1H-CPU67H HOST CONNECTION MANUAL.
Analog Output Units for converting ,
binary data into analog output signals. Name: Compact Connectors.
Specifications: Outputs; 4 inputs; NPN.
Bit slave of smallest class in industry,
Innovation in wiring for any type of machinery.
Available in 2 types: 2-point Bit Slave Unit,
and 4-point Bit Slave Unit.
Compact size for installation in limited space.
Save space and wiring since bit slave can be,
installed near I/O devices CJ1H-CPU67H HOST CONNECTION MANUAL.
Industry first bit slave connectable with round,
cables which can be easily purchased at a lower price.
Connectable with flat cables, too for easy wiring.
Cables are selectable depending on applications. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100.
Conversion speed (resolution):
250 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 26V, --.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spaace compared,
with previous systems CJ1H-CPU67H Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CJ1H-CPU67H Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.