Meet the standard interface IEEE-488-1978 (GP-IB).Model: C200H-ID216.
No. of points: 64 pts.
Specifications: 24VDC.
Weight: 180g max.Unit type: 10 I/O points 6 inputs; 4 outputs, Connector.
Input: 6 points: 24 VDC.
Output: 4 points: transistor (sinking).
Clock: Yes.
Slaves with the Complex Functionality Needed,
for Distributed Blocks C200H-TS001 INSTRUCTION SHEET.
Programmable Slaves combine devices, such as sensors and actuators,
into one functional unit that is treated as a DeviceNet slave
C200H-TS001
Programmable Slaves greatly facilitate device distribution,
and functional organization.
They help standardize programming between units and reduce the amount of,
programming required at the master.
I/O and operational checks can be performed for each functional unit,
rather than waiting C200H-TS001 INSTRUCTION SHEET.
for final system assembly, as with conventional distributed I/O systems.Number of inputs: 32 pts.
Input Voltage: 12 V DC.
Input Current: 4 mA.Unit classifi cation: CS1 CPU Bus Unit.
Product name:Controller Link Unit.
Specifications: Communications cable,
Wired shielded twisted-pair cable;
Communications type, Data links and,
message service; Duplex support, No C200H-TS001 INSTRUCTION SHEET.
Max. Units mountable per CPU Unit, 8.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.33A; 26V, --.
Standards: UC1, N, L, CE.
New Controller Link Units,
Now with 4,000 Send Words.
The Controller Link is an,
FA network that can send,
and receive large amounts,
of data easily and at high speed.
The Controller Link supports data,
links that enable sharing data between,
PLCs and computers and a message service,
that enables sending and receiving,
data whenever required.
With Wired Controller Link Units,
systems can be flexibly built by using,
Repeater Units to enable T branches,
long-distance wiring, and converting,
part of the network to optical cable. Product name: Transistor Output Units.
Specifications: Output type, Sourcing;
I/O points, 16 outputs;
Maximum switching capacity, 24VDC,
0.5A Short-circuit protection;
Commons, 16 points, 1 common;
External connection, Removable terminal block.
No. of words allocated: 1 word.
Current consummption: 5V, 0 C200H-TS001 Manual. 10A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices C200H-TS001 Manual.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput.