3G2A5-IDS21 INSTRUCTION SHEET ()
Product model: 3G2A5-IDS21
Name: Safety Light Curtain
Brand: OMRON
Sort: INSTRUCTION SHEET
File language: English
Cable length: 3m.
A digital operator is installed in a place far away from the transducer. Specification: three phase 400V.
Power: 1.5KW.
Maximum output voltage: three phase AC380 ~ 480V (input voltage correspondence).
Rated voltage: three phase 480V ~ 50/60Hz AC380.
Weight: about 4kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive 3G2A5-IDS21 INSTRUCTION SHEET 3G2A5-IDS21
The high functional specifications are concentrated in the compact.
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software 3G2A5-IDS21 INSTRUCTION SHEET.
DeviceNet correspondence correspondence.
Multi function input and output function.
Colorful function.
Brake transistor built-in.
Protection function. When the power supply capacity exceeds the power supply capacity of the inverter or the need to improve the power factor, it is required to connect the AC reactor.
Please according to the maximum capacity of heavy load and light load rated conditions suitable for motor to select option 3G2A5-IDS21 INSTRUCTION SHEET. Applicable converter capacity: maximum 5.5KW, minimum 0.1KW.
Connected to the converter input / output cable,
Reduce the noise from the power supply line to the frequency converter or from the converter to the power line. When the power supply capacity exceeds the power supply capacity of the inverter or the need to improve the power factor, it is required to connect the AC reactor.
Please according to the maximum capacity of heavy load and light load rated conditions suitable for motor to select option. 3G2A5-IDS21 Manual. Specification: small.
Impact resistance: 120W.
Resistance to impact resistance: 100.
The use of resistance to consume the motor regenerative energy, thereby reducing the time to slow down.
Alarm output terminal of braking resisttor 3G2A5-IDS21 Manual.
When the temperature relay of the braking resistor is activated, a circuit for cutting the main power supply of the frequency converter is formed.
Related products
OMRON
Input Module
C500-ID212(3G2A5-ID212)
OMRON Input Module C500-ID212(3G2A5-ID212)
C500-ID I/O Unit DC Input 64 pts C500-ID
OMRON
Triac Output Unit
C500-OA222(3G2A5-OA222)
OMRON Triac Output Unit C500-OA222(3G2A5-OA222)
C500-OA I/O Unit Triac Output 16 pts C50
OMRON
SYSBUS Remote I/O Unit
C500-RM001-V1(3G2A5-RM001-V1)
OMRON SYSBUS Remote I/O Unit C500-RM001-V1(3G2A5-RM001-V1)
C500-RM SYSMAC BUS Remote I/O Master Wir
OMRON
Input Module
C500-ID215(3G2A5-ID215)
OMRON Input Module C500-ID215(3G2A5-ID215)
C500-ID I/O Unit DC Input 32 pts C500-ID