Power rating: 75 W.
Input voltage: 100 to 240 VAC (allowable range: 85 to 264 VAC or 120 to 370 VDC*1).
Output voltage: 48 V VDC.
Output current: 1.6 A.
Built-in fan: None.
Model with terminal block facing upward.
High Reliability at a Reasonable Cost.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation SRT2-VOD16ML PDF datasheet.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage
SRT2-VOD16ML
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life. A reliable 3-year warranty.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications SRT2-VOD16ML PDF datasheet.
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W. Power ratings: 90 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1 SRT2-VOD16ML PDF datasheet.
Output voltage: 24 V.
Output current: 3.75 A.
Alarm output *2: Sinking.
UL Class 2 Output standards: Yes.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Control power supply voltage: 48 VDC.
Input: DC, Input voltage range, 10 to 300 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Available in 7 supply voltage configurations SRT2-VOD16ML PDF catalog.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrse current detection SRT2-VOD16ML PDF catalog.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).