I/O classification: Digital output.
Internal I/O circuit common: PNP (+ common).
I/O points: 8.
I/O connection method: Sensor connector.
Compact Remote I/O Terminals that.
Save Wiring Effort and Enable.
Long-distance Communications.
Long-distance or high-speed communications,
mode is selectable S8BA-24D24D240LF PDF datasheet.
Incorporates I/O connectors making it possible to,
minimize the size
S8BA-24D24D240LF
I/O connectors save wiring effort.
Flexible DIN track mounting is possible through a,
DIN track attachment.
Eight-point sensor connector models and 16-point,
MIL connector models are the same size. Terminal/mounting: Plug-in/DIN rail via socket.
Control voltage: 200/220/240 VAC.
Overcurrent detection: Instantaneous type, W/o start-up lock S8BA-24D24D240LF PDF datasheet.
Solid-state, Plug-in Current Sensor.
Applicable to motor overcurrent protection and 3-phase AC current detection.
Inverse-type, start-up lock type, and instantaneous type over,
current sensors available.
Instantaneous type under current sensor available.
Plug-in design simplifies installation, removal, and wiring.
DIN sized (48 mm x 96 mm). I/O classification: Input S8BA-24D24D240LF PDF datasheet.
Internal I/O circuit common: NPN (+ common).
I/O points: 8.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Long-distance Communications Supported by SRT2 Models,
(Long-distance/High-speed Communications Selection).
Ultra-compact at 80 x 48 x 50 (W x H x D) mm for,
4-point and 8-point terminals and 105 x 48 x 50,
(W x H x D) mm for 16-point terminals.
Two independent power supplies can be used,
because the I/O terminals are insulated from the internal circuits.
DIN track mounting and screw mounting are both supported. Control power supply voltage: 100/110 VAC.
Input: DC or AC (selectable); input voltage range: 10 to 300 V: Operating mode,
ON-delay; OFF-delay; Startup lock.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Available in 77 supply voltage configurations S8BA-24D24D240LF PDF catalog.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrse current detection S8BA-24D24D240LF PDF catalog.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).