Construction: insert / solder terminal.
Contact form: 4PDT.
Indicator: no light.
Note: when the order is ordered, the number of the models is added with the rated voltage of the coil.
For example: DC12 DC12, LY1-J on behalf of the rated voltage of the coil.
Arc barrier equipped with high insulation strength (AC2000V) LY2N-CR PDF datasheet. Construction: insert / solder terminal.
Contact form: SPDT
LY2N-CR
Indicator: no light.
Note: when the order is ordered, the number of the models is added with the rated voltage of the coil.
For example: DC12 DC12, LY1-J on behalf of the rated voltage of the coil.
Arc barrier equipped with high insulation strength (AC2000V). Structure: PCB terminal.
Contact form: DPDT.
Indicator: no light LY2N-CR PDF datasheet.
Note: when the order is ordered, the number of the models is added with the rated voltage of the coil.
For example: DC12 DC12, LY1-J on behalf of the rated voltage of the coil.
Arc barrier equipped with high insulation strength (AC2000V). Arc barrier equipped with high insulation strength (AC2000V)Detected voltage: DC.
Compact, Economical Plug-in Type Voltage.
Sensing Relay LY2N-CR PDF datasheet.
DPDT output contacts expand the application of the Sensor to,
wide-ranging fields including control, alarms, and indication.
Voltage control is possible in the same easy manner as electro,
magnetic relays, as the output relay of the sensor can be driven,
directly with a detection signal.
Wide voltage setting range with fine setting capability. Construction: insert / solder terminal.
Contact form: 3PDT.
Indicator: led.
Note: when the order is ordered, the number of the models is added with the rated voltage of the coil.
For example: DC12 DC12, LY1-J on behalf of the rated voltage of the coil.
Arc barrier equipped with high insulation strength (AC2000V). Structure: Relays with Plug-in Terminals, With operation indicators.
Classification: Models with diode for coil surge,
absorption (DC coil specification only).
Number of poles: 2 Bifurcated.
Power-switching Compact.
General-purpose Relays.
The standard models include models that are,
compliant with the UL, CSA, and SEV safety.
standards and with the Electrical Appliances and,
Material Safety Act.
Equipped with an arc barrier for arc interruption.
Withstand voltages up to 2,000 V.
New built-in diode and built-in CR circuit models have,
joined the series.
The lineup also inncludes models that are compliant,
with the LR and VDE safety standards LY2N-CR PDF catalog.
Single-pole and double-pole models have AC4,
ratings and DC2 ratings (operating coil ratings:
100/110 VAC, 110/120 VAC, 200/220 VAC, 220/240 VAC,
and 1100/110 VDC) LY2N-CR PDF catalog.
Three-pole and four-pole models have AC4 ratings,
and DC2 ratings (operating coil ratings: 100/110,
VAC, 200/220 VAC and 100/110 VDC).