LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Catalog Download
K8AB-PA2 PDF datasheet (datasheet)
Product model: K8AB-PA2
Name: Three-phase Asymmetry
Brand: OMRON
Sort: PDF datasheet
File language: English
Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element K8AB-PA2 PDF datasheet.
Burnout Detector compatible with a,
wide-range of heater control methods K8AB-PA2
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance K8AB-PA2 PDF datasheet.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Standard function model: detection of under voltage.
Appearance: ADR shell.
Open circuit: voltage, no voltage, DC circuit breaker.
Rated voltage: AC110V K8AB-PA2 PDF datasheet.
Rated frequency: 50/60Hz.
Voltage adjustment range: 60-65-70-75-80-85-90V (7 shunt).
Time hopping: timing; -0.2-0.4-0.6-0.8-1.0
-1.2-1.4-1.6-1.8-2.0s (11 shunt).
Control power supply: No, and input common; there, DC operation.
Rating consumption VA: No, 6VA (input side);
Have, 2VA (input side) 10W (control power supply side).
Control: 1C, 1A AC110V 7.5Acos output with =0.4
(max 250V 825VA AC);
24V 5A L/R=7ms DC (max 125V 50W when DC).
Display: start display (LED display),
Action display (trip) manual reset.
Automatic experiment: -.
Quality: about 2kg.
External: Mount Searl N1.5.
Static voltage relay.
K2VR-S/K2VA-S type, high action reliability disk with static type UVR/OVR.
Accurate work thrrough high reliability semiconductor circuits K8AB-PA2 PDF catalog.
Type K2VU-S1 is the output contact, but will be closed when the voltage is not enough,
Therefore, the locking time sequence circuit of the circuit breaker is not required.
Within thhe hidden from the start to the 2S timer, can easily adjust the time K8AB-PA2 PDF catalog.
The control power of the relay is not needed, which avoids the trouble of wiring.
Related products
OMRON
Single-phase Voltage Relay
K8AB-VS3 AC/DC24V
OMRON Single-phase Voltage Relay K8AB-VS3 AC/DC24V
Measuring voltage: 20 to 200 V AC/DC, 30
OMRON
Single-phase Voltage Relay
K8AB-VW2 AC100/115V
OMRON Single-phase Voltage Relay K8AB-VW2 AC100/115V
Measuring voltage: 1 to 10 V AC/DC, 3 to
OMRON
Power Supply Module
C200HW-PA209R
OMRON Power Supply Module C200HW-PA209R
Model: C200HW-PA209R. Supply voltage: 10
OMRON
Temperature Monitoring Relay
K8AB-TH12S AC/DC24
OMRON Temperature Monitoring Relay K8AB-TH12S AC/DC24
Size: K8AB-TH 22.5 × 90 × 100 mm. Suppl