Digital Rotary Pulse Meter Capable of 50 kHz Measurements.
Visual confirmation of judgement results through display colors that switch,
between red and green.
Measures High-speed Pulses at 50 kHz.
Provides high-speed pulse measurements up to 50 kHz of rotary encoder,
or ON/OFF pulse.
signals and can perform rotating measurement of high-speed rotating objects K8AB-AS3 AC/DC24V PDF datasheet.
Note: No-voltage contacts of up to 30 Hz are supported
K8AB-AS3 AC/DC24V
Six Measurement Operations Including Rotation (rpm)/Circumferential,
Speed, Ratio, and Cumulative.
One Rotary Pulse Meter has 6 rotary pulse measurement functions to,
support a variety.
of pulse measurement applications. Select the best function for your,
application from the K8AB-AS3 AC/DC24V PDF datasheet.
following: Rotation (rpm)/circumferential speed/instantaneous flowrate,
(value proportional to frequency), absolute ratio, error ratio, error,
flow rate ratio, and passing.
speed (value inversely proportional to frequency).
DeviceNet models added to the series. Ideal for 3-phase Voltage Asymmetry.
Monitoring for Industrial Facilities and Equipment.
Greater resistance to inverter noise K8AB-AS3 AC/DC24V PDF datasheet.
Monitor voltage asymmetry, phase sequence, and phase,
loss for three-phase 3-wire or 4-wire power supplies with just one Unit.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply.
One SPDT output relay, 5 A at 250 VAC (resistive load).
World-wide power specifications supported by one Unit (switchable).
Relay status can be monitored using LED indicator. Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation K8AB-AS3 AC/DC24V PDF catalog.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K8AB-AS3 AC/DC24V PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.