LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Catalog Download
K8AB-AS3 AC/DC24V PDF datasheet (datasheet)
Product model: K8AB-AS3 AC/DC24V
Name: Single-phase Current Relay
Brand: OMRON
Sort: PDF datasheet
File language: English
Setting range: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC.
Power supply voltage: 24 VAC/DC.
Ideal for Voltage Monitoring for.
Industrial Facilities and Equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 5 A at 250 VAC (resistive load) K8AB-AS3 AC/DC24V PDF datasheet.
Output relay can be switched between normally open and normally closed K8AB-AS3 AC/DC24V
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Static voltage relay.
K2VR-S/K2VA-S type, high action reliability disk with static type UVR/OVR K8AB-AS3 AC/DC24V PDF datasheet.
Accurate work through high reliability semiconductor circuits.
Type K2VU-S1 is the output contact, but will be closed when the voltage is not enough,
Therefore, the locking time sequence circuit of the circuit breaker is not required.
Within the hidden from the start to the 2S timer, can easily adjust the time.
The control power of the relay is not needed, which avoids the trouble of wiring K8AB-AS3 AC/DC24V PDF datasheet.
Measuring voltage: 6 to 60 mV AC/DC, 10 to 100 mV AC/DC, 30 to 300 mV AC/DC.
Supply voltage: 200-230 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and,
undervoltages.
Manual resetting and automatically resetting supported by one Relay.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Control supply voltage: 110/220 VAC; Without voltage fluctuation compensation.
Operating current: 2 to 4 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned elemennt even if one heater el,
ement among several heater elements has been burned out K8AB-AS3 AC/DC24V PDF catalog.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with booth single-phase and three-phase heaters K8AB-AS3 AC/DC24V PDF catalog.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.
Related products
OMRON
Rotating pulse meter
K3HB-RPB-A AC/DC24V
OMRON Rotating pulse meter K3HB-RPB-A AC/DC24V
Input type: PNP input type. Event input
OMRON
Time interval table
K3HB-PPB-A1 AC/DC24V
OMRON Time interval table K3HB-PPB-A1 AC/DC24V
Input type: PNP input type. Event input
OMRON
Time interval table
K3HB-PNB-FLK1AT11 AC/DC24V
OMRON Time interval table K3HB-PNB-FLK1AT11 AC/DC24V
Input type: NPN/ voltage pulse input typ