Static over current relay type K2CA-D, attention to the protection of the coordination of static type OCR.
The protection coordination between OCR and MCCB is simple.
1 sets of three-phase protection, can save space and manpower.
Compared with the plate movement start display, through time display, make maintenance and inspection becomes simple K3MA-L-C AC/DC24V PDF datasheet.
The display of the accident occurrence phase is used to facilitate the inspection after the accident
K3MA-L-C AC/DC24V
Reduce the consumption of VA, reduce the burden of converter. Type of input: platinum resistance / thermocouple input.
Event input terminal 4 points (TIMING, S-TIM, HOLD, RESET) is equipped with.
No output: -.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V K3MA-L-C AC/DC24V PDF datasheet.
Temperature indicator and measurement of various processes.
Action determine the color, can switch the green / Red 2 kinds of color display.
High speed sampling of 50 /s (20ms).
0.01 degree: platinum temperature resistance body Pt100 high resolution.
Thermocouple sensor (full range) to support the resolution of 0.1.
The temperature input compensation can be easily set by 2 points K3MA-L-C AC/DC24V PDF datasheet.
Series of DeviceNet type.
UL standard applicable certification (standardCategory: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Transistor: -; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event inputTime specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,,
is indicated from the start of operation K3MA-L-C AC/DC24V PDF catalog.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeency, basic,
frequency, and load conditions K3MA-L-C AC/DC24V PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,