K3MA-F AC100-240V PDF datasheet (datasheet)
Product model: K3MA-F AC100-240V
Name: Frequency/Rate Meter
Brand: OMRON
Sort: PDF datasheet
File language: English
Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K3MA-F AC100-240V PDF datasheet.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K3MA-F AC100-240V
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3MA-F AC100-240V PDF datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note K3MA-F AC100-240V PDF datasheet. ).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Function: Phase sequence and phase loss monitoring.
Rated input voltage: 3-phase, 3-wire 200 to 480 VAC.
Relay output: SPDT × 1.
Three-phase Phase-sequence Phase-loss.
Relay Using VVoltage Detection Method K3MA-F AC100-240V PDF catalog.
Lineup includes a 17.5-mm slim, compact model.
Greater resistance to inverter noise.
Distinguishes between correct phases, phase sequence, and phase,
loss when power is turned ON.
Supportss phase loss detection when the motor is operating K3MA-F AC100-240V PDF catalog.
Output status can be monitored using LED indicator.
Ideal to prevent reverse operation of motors.
Related products
OMRON
Single-phase Current Relay
K8AK-AS1 100-240VAC
OMRON Single-phase Current Relay K8AK-AS1 100-240VAC
Setting range: 2 to 20 mA AC/DC, 10 to 1
OMRON
Conductive Level Controller
K8AK-LS 100-240VAC
OMRON Conductive Level Controller K8AK-LS 100-240VAC
Power supply voltage: 100 to 240 VAC. I
OMRON
Single-phase Voltage Relay
K8AK-VS3 100-240VAC
OMRON Single-phase Voltage Relay K8AK-VS3 100-240VAC
Setting range: 20 to 200 V AC/DC, 30 to