K3HB-XVD-CPAC11 AC100-240 PDF datasheet (datasheet)
Product model: K3HB-XVD-CPAC11 AC100-240
Name: Voltage and current panel meter
Brand: OMRON
Sort: PDF datasheet
File language: English
Input type: DC voltage input type.
Output type: relay contact; 1c HH; PASS, H, L, LL: each 1a.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth K3HB-XVD-CPAC11 AC100-240 PDF datasheet.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-XVD-CPAC11 AC100-240
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNet type systemCollection housing: square type shell embedded ADR shell K3HB-XVD-CPAC11 AC100-240 PDF datasheet.
Purpose: high voltage non grounded system; high voltage PC (reactor) grounding system.
Digital ground directional relay K2GS-H type,
Can measure the zero phase current, zero phase voltage of the digital DGR.
And automatic test equipment can be used to test the relay conveniently.
Can be set for the coordination of a small number of hours to adjust the time K3HB-XVD-CPAC11 AC100-240 PDF datasheet.
Improve reliability by monitoring function at any time.
LED can be used to confirm the occurrence of anomalies.
The forced action of the experimental switch can be easily recognized.
Based on the DIN standard size, the depth is only small size 88.5mm. (except for terminal units)
Setting range: 0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC.
Power supply voltage: 100 to 240 VAC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents and undercurrents simultaneously.
Separate settings and outputs supported for overcurrents and undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A) K3HB-XVD-CPAC11 AC100-240 PDF catalog.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
Two sets of SSPDT output contacts, 5 A at 250 VAC (resistive load) K3HB-XVD-CPAC11 AC100-240 PDF catalog.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply.