K3HB-XVD-CPAC11 AC/DC24 PDF datasheet (datasheet)
Product model: K3HB-XVD-CPAC11 AC/DC24
Name: Voltage and current panel meter
Brand: OMRON
Sort: PDF datasheet
File language: English
Function: Phase sequence and phase loss monitoring.
Rated input voltage: 3-phase, 3-wire 200 to 480 VAC.
Relay output: DPDT ×1.
Three-phase Phase-sequence Phase-loss.
Relay Using Voltage Detection Method.
Greater resistance to inverter noise.
Distinguishes between correct phases, phase sequence, and phase,
loss when power is turned ON K3HB-XVD-CPAC11 AC/DC24 PDF datasheet.
Supports phase loss detection when the motor is operating K3HB-XVD-CPAC11 AC/DC24
5 A (resistive load) at 250 VAC, DPDT x 1.
Output status can be monitored using LED indicator.
Ideal to prevent reverse operation of motors. Rated input (See note 2.): 3-phase 3-wire mode, 3-phase 4-wire mode;
380, 400, 415, 480 VAC, 220, 230, 240, 277 VAC.
Ideal for monitoring 3-phase power supplies K3HB-XVD-CPAC11 AC/DC24 PDF datasheet.
for industrial facilities and equipment.
Monitor overvoltages, undervoltages, phase sequence, and,
phase loss for three-phase 3-wire or 4-wire power supplies with,
just one Unit.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power,
supply.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Output overvoltages and undervoltages using separate relays.
World-wide power specifications supported by one Unit,
(switchable) K3HB-XVD-CPAC11 AC/DC24 PDF datasheet.
Output status can be monitored using LED indicator. Measuring current: 10 to 100 A AC, 20 to 200 A (See note.).
Supply voltage: 24 VAC/DC.
Ideal for current monitoring for,
industrial facilities and equipment.
Monitor for overcurrents or undercurrents.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and,
normally closed.
Process control signal (4 to 20 mA) and commercial CT input,
(0 to 1 A or 0 to 5 A) supported.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents and undercurrents simultaneously.
Separate settings and outputs supported for overcurrents and undercurrents.
Use commerciallly available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A) K3HB-XVD-CPAC11 AC/DC24 PDF catalog.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
Two sets of SSPDT output contacts, 5 A at 250 VAC (resistive load) K3HB-XVD-CPAC11 AC/DC24 PDF catalog.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply.