K3HB-XVA-BCD1 AC/DC24 PDF datasheet (datasheet)
Product model: K3HB-XVA-BCD1 AC/DC24
Name: Voltage and current panel meter
Brand: OMRON
Sort: PDF datasheet
File language: English
Input type: DC voltage input type.
Output type: no output.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-XVA-BCD1 AC/DC24 PDF datasheet K3HB-XVA-BCD1 AC/DC24
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm K3HB-XVA-BCD1 AC/DC24 PDF datasheet. Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Linearity: voltage; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table K3HB-XVA-BCD1 AC/DC24 PDF datasheet.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, maximum measurable fromTime specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
iss indicated from the start of operation K3HB-XVA-BCD1 AC/DC24 PDF catalog.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeency, basic,
frequency, and load conditions K3HB-XVA-BCD1 AC/DC24 PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
Related products
OMRON
Temperature panel
K3HB-HTA-BCD1 AC/DC24
OMRON Temperature panel K3HB-HTA-BCD1 AC/DC24
Type of input: platinum resistance / the
OMRON
Rotating pulse meter
K3HB-RPB-ABCD1 AC/DC24V
OMRON Rotating pulse meter K3HB-RPB-ABCD1 AC/DC24V
Input type: PNP input type. Event input
OMRON
Time interval table
K3HB-PNB-ABCD1 AC/DC24V
OMRON Time interval table K3HB-PNB-ABCD1 AC/DC24V
Input type: NPN/ voltage pulse input typ