Input type: high speed response type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External power supply DC12V80mA.
Output type: linear; current; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
High speed, high precision measurement, determine the color display,
Can switch the green / Red 2 kinds of display colors K3HB-XAD-FLK3AT11 AC100-240 PDF datasheet
K3HB-XAD-FLK3AT11 AC100-240
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm.
UType of input: platinum resistance / thermocouple input K3HB-XAD-FLK3AT11 AC100-240 PDF datasheet.
Event input terminal 4 points (TIMING, S-TIM, HOLD, RESET) is equipped with.
BCD+ transistor: -- NPN open collector (5 bit output +HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Temperature indicator and measurement of various processes.
Action determine the color, can switch the green / Red 2 kinds of color display.
High speed sampling of 50 /s (20ms) K3HB-XAD-FLK3AT11 AC100-240 PDF datasheet.
0.01 degree: platinum temperature resistance body Pt100 high resolution.
Thermocouple sensor (full range) to support the resolution of 0.1.
By 2 points can be easily setInput type: PNP input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
No output: -.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Digital rotating pulse meter with high speed measurement for 50kHz.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of 50kHz high speed pulse.
Rotary encoder and a variety of ON/OFF pulse signals, the most up to 50kHz of high-speed pulse measurement.
Rotation measurement of high speed rotating objects can be carried out.
SupportOpen circuit mode: current circuit breaker.
Appearance: ADR shell.
Rated current: AC110V.
Rated frequency: 50/60Hz.
Consume VA: action time 10VA below (except for reactor part).
Action current adjustment range (zero phase converter primary current):
0.1-0.2-0.3-0.4-0.6A (5 shunt).
Control output: 1A; closed circuit 110V 15A DC 1000 (L/R=0ms),
Open 110V 1A DC 1000 (L/R=25ms).
The relay control output circuit breaker switch: power capacity, switching capacity, AC110V/10A C110V/10A; (COS =1).
Quality: about 1kg.
External: Mount Searl N1.5.
High voltage grounding relay type K2GA thin,
Miniaturization, and digital type precision mounting K3HB-XAD-FLK3AT11 AC100-240 PDF catalog.
Strong anti interference ability,
Stable operation in the arc grounding fault.
Can carry out fine current adjjustment, easy to coordinate K3HB-XAD-FLK3AT11 AC100-240 PDF catalog.
Set alarm terminal.
The adjusting part of the action current is a rotary switch mode, which is convenient for adjustment.