LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Catalog Download
K3HB-XAD-FLK1AT11 AC/DC24 PDF datasheet (datasheet)
Product model: K3HB-XAD-FLK1AT11 AC/DC24
Name: Voltage and current panel meter
Brand: OMRON
Sort: PDF datasheet
File language: English
Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element K3HB-XAD-FLK1AT11 AC/DC24 PDF datasheet.
Burnout Detector compatible with a,
wide-range of heater control methods K3HB-XAD-FLK1AT11 AC/DC24
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance K3HB-XAD-FLK1AT11 AC/DC24 PDF datasheet.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Measuring current: 10 to 100 A AC, 20 to 200 A (See note.).
Supply voltage: 24 VAC/DC.
Ideal for current monitoring for,
industrial facilities and equipment K3HB-XAD-FLK1AT11 AC/DC24 PDF datasheet.
Monitor for overcurrents or undercurrents.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and,
normally closed.
Process control signal (4 to 20 mA) and commercial CT input,
(0 to 1 A or 0 to 5 A) supported.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Rated input (See note 2.): 3-phase 3-wire mode, 3-phase 4-wire mode;
380, 400, 415, 480 VAC, 220, 230, 240, 277 VAC.
Ideal for monitoring 3-phase power supplies.
for industrial facilities and equipment.
Monitor overvoltages and undervoltages for three-phase 3-wiree,
or 4-wire power supplies K3HB-XAD-FLK1AT11 AC/DC24 PDF catalog.
DIP switch setting for 3-phase 3-wire or 3-phase 4-wire power supply.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Separate outputs possible for overvoltages and undeervoltages K3HB-XAD-FLK1AT11 AC/DC24 PDF catalog.
World-wide power specifications supported by one Unit,
(switchable using DIP switch).
Relay status can be monitored using LED indicator.
Related products