Economical, Compact, High-performance,
DIN 48 × 48-mm Ground Fault Relay for Low,
Voltages.
Performs continuous monitoring and detection of ground faults,
in low-voltage circuits due to the deterioration of insulation in,
electrical devices.
Higher reliability ensured with improved resistance to high-fre,
quency noise when used for inverter loads K3HB-SSD-AT11 AC/DC24 PDF datasheet.
Ground Fault Relays and through-type ZCTs (zero-phase current,
transformers) are mutually compatible
K3HB-SSD-AT11 AC/DC24
The through-type ZCTs are equipped with test terminals,
allowing operation tests for Ground Fault Relays to be performed withease. Size: K8AB-TH 22.5 × 90 × 100 mm.
Supply voltage: 100 to 240 VAC.
Type: Temperature input.
Number of outputs: 1 (relay) K3HB-SSD-AT11 AC/DC24 PDF datasheet.
Input type: Thermocouple/Pt100.
Setting unit (setting range): Unit: 1°C/°F (0 to 399°C/°F).
Compact and Slim Relay Ideal for.
Temperature Alarms and Monitoring.
Excessive temperature increases can be prevented and,
abnormal temperatures can be monitored.
Temperature monitoring in slim design with a width of just 22.5 mm.
Simple function settings using DIP switch.
Universal-input support for thermocouple or Pt100 sensor input K3HB-SSD-AT11 AC/DC24 PDF datasheet.
Selectable output relay: Non-fail safe/fail safe.
Alarm status identification with LED indicator. Input type: PNP input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
No output: -.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Digital rotating pulse meter with high speed measurement for 50kHz.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of 50kHz high speed pulse.
Rotary encoder and a variety of ON/OFF pulse signals, the most up to 50kHz of high-speed pulse measurement.
Rotation measurement of high speed rotating objects can be carried out.
Support without electricityFunction: Phase sequence and phase loss monitoring.
Rated input voltage: 3-phase, 3-wire 200 to 480 VAC.
Relay output: DPDT ×1.
Three-phase Phase-sequence Phase-loss.
Relay Using VVoltage Detection Method K3HB-SSD-AT11 AC/DC24 PDF catalog.
Greater resistance to inverter noise.
Distinguishes between correct phases, phase sequence, and phase,
loss when power is turned ON.
Supports phase loss detection when the motor is operrating K3HB-SSD-AT11 AC/DC24 PDF catalog.
5 A (resistive load) at 250 VAC, DPDT x 1.
Output status can be monitored using LED indicator.
Ideal to prevent reverse operation of motors.