K3HB-RPB-L1AT11 AC100-240 PDF datasheet (datasheet)
Product model: K3HB-RPB-L1AT11 AC100-240
Name: Rotating pulse meter
Brand: OMRON
Sort: PDF datasheet
File language: English
Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K3HB-RPB-L1AT11 AC100-240 PDF datasheet.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K3HB-RPB-L1AT11 AC100-240
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-RPB-L1AT11 AC100-240 PDF datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three K3HB-RPB-L1AT11 AC100-240 PDF datasheet.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cycclic control K3HB-RPB-L1AT11 AC100-240 PDF catalog.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K3HB-RPB-L1AT11 AC100-240 PDF catalog.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
Related products
OMRON
Time interval table
K3HB-PNB-L1AT11 AC100-240
OMRON Time interval table K3HB-PNB-L1AT11 AC100-240
Input type: NPN/ voltage pulse input typ
OMRON
Time interval table
K3HB-PNB-L2AT11 AC100-240
OMRON Time interval table K3HB-PNB-L2AT11 AC100-240
Input type: NPN/ voltage pulse input typ
OMRON
Time interval table
K3HB-PPB-AT11 AC100-240
OMRON Time interval table K3HB-PPB-AT11 AC100-240
Input type: PNP input type. Event input