K3HB-PNB-ABCD1 AC100-240 PDF datasheet (datasheet)
Product model: K3HB-PNB-ABCD1 AC100-240
Name: Time interval table
Brand: OMRON
Sort: PDF datasheet
File language: English
Measuring voltage: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC.
Supply voltage: 100-115 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and,
undervoltages K3HB-PNB-ABCD1 AC100-240 PDF datasheet.
Manual resetting and automatically resetting supported by one Relay K3HB-PNB-ABCD1 AC100-240
Pre-alarm Monitoring Mode.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Input type: DC current input K3HB-PNB-ABCD1 AC100-240 PDF datasheet.
Output type: communication; RS-485; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-PNB-ABCD1 AC100-240 PDF datasheet.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNIdeal for 3-phase Voltage Asymmetry.
Monitoring for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor voltage asymmetry, phase sequence, and phase,
loss for three-phase 3-wire or 4-wire power supplies with just one Unit.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply.
One SPDT output relay, 5 A at 250 VAC (resistive load).
World-wide power specifications supported by one Unit (switchable).
Relay status can be monitored using LED indicator. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyyclic control K3HB-PNB-ABCD1 AC100-240 PDF catalog.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K3HB-PNB-ABCD1 AC100-240 PDF catalog.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
Related products
OMRON
Time interval table
K3HB-PPB-ABCD1 AC100-240
OMRON Time interval table K3HB-PPB-ABCD1 AC100-240
Input type: PNP input type. Event input
OMRON
Temperature panel
K3HB-HTA-BCD1 AC100-240
OMRON Temperature panel K3HB-HTA-BCD1 AC100-240
Type of input: platinum resistance / the
OMRON
Load sensor, mV instrument
K3HB-VLC-EBCD1 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-EBCD1 AC100-240
Category: external supply 100mA DC5V typ