LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Catalog Download
K3HB-HTA-FLK1AT11 AC100-240 PDF datasheet (datasheet)
Product model: K3HB-HTA-FLK1AT11 AC100-240
Name: Temperature panel
Brand: OMRON
Sort: PDF datasheet
File language: English
Applicable Current Transformer.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control K3HB-HTA-FLK1AT11 AC100-240 PDF datasheet.
High-precision heater burnout alarm with digital measurement K3HB-HTA-FLK1AT11 AC100-240
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@) K3HB-HTA-FLK1AT11 AC100-240 PDF datasheet. Category: external supply 100mA DC5V type.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Relay contact: HH; PASS1c, H, L, LL: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K3HB-HTA-FLK1AT11 AC100-240 PDF datasheet.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurementSetting range: 0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC.
Power supply voltage: 24 VAC/DC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents and undercurrents simultaneously.
Separate settings and outputs supported for overcurrents and undercurrents.
Use commercially avvailable CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A) K3HB-HTA-FLK1AT11 AC100-240 PDF catalog.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
Two sets of SSPDT output contacts, 5 A at 250 VAC (resistive load) K3HB-HTA-FLK1AT11 AC100-240 PDF catalog.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply.
Related products