K2CM-Q4M PDF datasheet (datasheet)
Product model: K2CM-Q4M
Name: Motor Protective Relay
Brand: OMRON
Sort: PDF datasheet
File language: English
Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K2CM-Q4M PDF datasheet.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K2CM-Q4M
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K2CM-Q4M PDF datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Input type: DC current input.
Output type: relay contact; 1c H; PASS, L: each 1c.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with K2CM-Q4M PDF datasheet.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
Depth (panelCategory: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
DeviceNet; DeviceNet:--.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, looad, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K2CM-Q4M PDF catalog.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equippped with the sub pressure gauge for monitoring the operation trend K2CM-Q4M PDF catalog.
External event inputs can be applied to a variety of measurement and identification
Related products
OMRON
Motor Protective Relay
K2CM-Q2MAV
OMRON Motor Protective Relay K2CM-Q2MAV
Time specification: Instantaneous type.
OMRON
Motor Protective Relay
K2CM-2LS
OMRON Motor Protective Relay K2CM-2LS
Time specification: Inverse type. Curren
OMRON
Motor Protective Relay
K2CM-1L
OMRON Motor Protective Relay K2CM-1L
Time specification: Inverse type. Curren
OMRON
Motor Protective Relay
K2CM-2LV
OMRON Motor Protective Relay K2CM-2LV
Time specification: Inverse type. Curren