Standard certification: No.
Insulation: photo coupler.
Zero trigger function: No.
Action indicator: there.
Applicable load of output: DC4 3A ~ 48V.
Input rated voltage: DC5 ~ 24V.
With the LY1, LY2 large power relay with the same shape of the G3H series, the new international standard certification (-VD type) G3RV-SR500-A AC100 PDF datasheet.
Achieved UL, CSA, EN (VDE certification) standard certification
G3RV-SR500-A AC100 (type -VD)
Socket terminal type of same size with LY (1 pole, 2 pole type).
A model with an action indicator to check the status of the input. (type N)EtherCAT-compatible encoder input terminal which,
enables high-speed and accurate control.
Two counter function available.
Pulse count within 32 bit range.
Maximum input pulse frequency of 4MHz,
(Line driver input after quadrature) G3RV-SR500-A AC100 PDF datasheet.
High-speed network EtherCAT enables,
high-speed and accurate control.
Selectable two input types:
Open collector input and line driver input.
Built-in two external latch inputs,
and one reset input.
Selectable node address settings: setting with,
rotary switches and setting on tool software.
Detachable screw terminal will facilitate,
the maintenance work G3RV-SR500-A AC100 PDF datasheet. Terminal (Wire connection): Screw terminal.
Classification: Microloads.
Latching lever (Test switch): No.
Rated input voltage: AC/DC, 48V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Input terminals: M3 terminals.
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 1 output (Heater Burnout Detection,
SSR Short-circuit Failure Detection, Common).
Applicable load (See note.): 2 to 35 A, 100 to 240 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures G3RV-SR500-A AC100 PDF catalog.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp termiinals (detachable), or compact slotted,
screw terminals (detachable) G3RV-SR500-A AC100 PDF catalog.
Certified for CSA and EN (TÜV).