Terminal (wire connection): Push-In Plus Terminal.
Applicable output load: AC load.
Zero cross function: No.
Rated input voltage: AC 100V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel G3PH-5075BL DC5-24 PDF datasheet
G3PH-5075BL DC5-24
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires G3PH-5075BL DC5-24 PDF datasheet.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Number of elements: 3.
Isolation method: Phototriac coupler.
Rated powersupply voltage: 12 to 24 VDC.
Input method: No-voltage input (open and short circuited input) G3PH-5075BL DC5-24 PDF datasheet.
Applicable monitor capacity (AC3): 0.75 kW (4.8 A), 200 to 220 VAC.
Monitor output: DC switching output.
New Models with AC Power Supply Input and,
Monitor Output Equivalent to Non-contact,
SPST-NO Join the G3J-T Series,
Limiting the starting current saves energy.
Certified for UL and CSA.
Mounts with screws or to DIN Track.
Compact design with heat sinks (3.7-kW models: 100 × 100 ×130 mm (W × H × D)).
Built-in snubber circuit and thyristor.
Built-in operation indicator. Name: Multi-channel Power Controller.
Number of control channels: 4.
Heater burnout detection: Not supported.
Load power supply voltage: 400 to 480 VAC.
Optimum Cycle Control for High-precision.
Control with Low Noise.
Smaller than a Normal Power Controller.
Enables low-noise power control in combination with zero-cross.
SSRs. (See note.).
One Controller can control up to 8 SSRs.
RS-485 communications to set manipulated variables and,
heater burnout detection. The Smart FB Librarry for the G3ZA,
can also be used G3PH-5075BL DC5-24 PDF catalog.
CE Marking.
Main Upgraded Functions.
Soft-start function added for lamp heaters.
Three-phase optimum cycle control added for three-phase heaters.
Combining with special CT for1550-A current detection G3PH-5075BL DC5-24 PDF catalog.
Note: The G3ZA must be used in combination with an SSR without the,
zero cross function when the soft-start function is used.