Classification: electric arc barrier.Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 40 A at 200 to 480 VAC.
Rated input voltage: 100 to 240 VAC.
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A G2RV-SR700 DC12 PDF datasheet.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series
G2RV-SR700 DC12
All models feature the same compact dimensions to provide a,
uniform mounting pitch.
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by TÜV G2RV-SR700 DC12 PDF datasheet.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)). Safety outputs: Instantaneous, 4PST-NO; OFF-delayed, --.
Auxiliary outputs: 1 (Solid-state).
Max. OFF-delay time: --.
Rated voltage: 24 VDC.
Complete line-up of compact units,
including OFF-delayed safety output models.
17.5 or 22.5 mm width to save mounting space.
Simple wiring using screw-less terminals.
Easy maintenance with status indicators G2RV-SR700 DC12 PDF datasheet.
One unit for various safety devices, from contact input to PNP input. Cable with connector (1 to 2) /G79-I_-_-D1,
G79-O_-_-D1, G79-M_-_-D1.
Size: A, 750mm; B, 500mm.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Insulation method: Photocoupler.
Operation indicator: Yes.
Zero cross function: --.
Applicable load: 2 A at 5 to 48 VDC.
Input rated voltage: 5 to 24 VDC.
SSR with Plug-in Terminals.
The Same Shape as the G2R-1-S.
Power Relays.
These I/O solid state relays can be mounted in OMRON.
G70A I/O Terminals.
Lineup includes Input Modules for microloads and Output,
Modules for standard loads.
Lineup also includes UL, CSA, and TÜV-certified models,
(-UTU models). Optimum Cycle Control for High-precision.
Control with Low Noise.
Smaller than a Normal Power Controller.
Enables low-noise power control in combination with zero-cross.
SSRs. (See note.).
One Controller can control up to 8 SSRs.
RS-485 communications to set manipulated variables and,
heater burnout detection. The Smart FB Libbrary for the G3ZA,
can also be used G2RV-SR700 DC12 PDF catalog.
CE Marking.
Main Upgraded Functions.
Soft-start function added for lamp heaters.
Three-phase optimum cycle control added for three-phase heaters.
Combining with special CT for1550-A current detection G2RV-SR700 DC12 PDF catalog.
Note: The G3ZA must be used in combination with an SSR without the,
zero cross function when the soft-start function is used.