Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes.
Rated output load: 3 A at 100 to 240 VAC (See note 1.).
Rated input voltage: 5 to 24 VDC.
International Standards for G3F Series,
Same Profile as MY Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”) G2RV-SR700-AP AC/DC48 PDF datasheet.
Socket type, same size as MY Power Relays
G2RV-SR700-AP AC/DC48
Operation indicator provided to confirm input.
(model numbers with “N” before the suffix). Terminal (wire connection): Screw terminal.
Applicable output load: DC load.
Zero cross function: --.
Rated input voltage: DC 12V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay G2RV-SR700-AP AC/DC48 PDF datasheet.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability G2RV-SR700-AP AC/DC48 PDF datasheet.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Type: output module.
Insulation: photo coupler.
Zero crossing function: No.
Action display light: No.
Output rated voltage: DC48 1.5A ~ 200V.
Input rated voltage: DC4 ~ 24V.
Logic circuit and load interface.
I/O solid state relay.
With the input module (AC, DC), the output module (AC, DC).
Product series, the color of each module to distinguish.
You can confirm the action of SSR by using the action display light.
Between input and output voltage 4000V. Number of phase: Single-phase.
Control terminal block: Terminal block with small slotted screws.
Type: Constant current.
Capacity: 60 A, 100 to 240 VAC.
Heater burnout detection: Yes.
Communications: Yes.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control.
RS-485 commuunications to set manipulated variables and,
monitor load current G2RV-SR700-AP AC/DC48 PDF catalog.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,,
and constant-current control G2RV-SR700-AP AC/DC48 PDF catalog.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified.