A High-capacity, High-dielectric-strength,
Multi-pole Relay Used Like a Contactor.
Miniature hinge for maximum switching power for motor loads,
as well as resistive and inductive loads.
No contact chattering for momentary voltage drops up to 50%,
of rated voltage.
Withstanding more than 4 kV between contacts that are differ,
ent in polarity and between the coil and contacts G2RV-SR500-AP AC100 PDF datasheet
G2RV-SR500-AP AC100
Flame-resistant materials (UL94V-0-qualifying) used for all in,
sulation material.
Standard models approved by UL and CSA. Compact, Low-cost, SSR Switching 5 to 20 A.
Wide load voltage range: 75 to 264 VAC. Both 100-V and,
200-V loads can be handled with the same model.
Dedicated, compact aluminum PCB and power elements used G2RV-SR500-AP AC100 PDF datasheet.
Built-in varistor effectively absorbs external surges.
Quick-connect #110 input terminals and #250 output,
connections. (#187 input terminals and #250 output,
connections are available.).
“-US” models certified by UL, CSA, and IEC/EN (TÜV). Input capacity: 16 points.
Rated current (ON current): 0.5 A/output,
4.0 A/common.
Internal I/O common: NPN.
Residual voltage: 1 G2RV-SR500-AP AC100 PDF datasheet. 2 V max.
(0.5 ADC, between each output,
terminal and the G terminal)
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common:
8 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current consumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 370 g max.
Expansion functions: No.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
A common terminal is provided for each contact.
It eliminate the needs for relay terminal blocks.
It is unnecessary to share the common terminal,
among multiple contacts.
Easy--to-find wiring locations G2RV-SR500-AP AC100 PDF catalog.
Detachable screw terminal block facilitates the maintenance.
Input response time can be switched for high-speed processing.
Selectable node address setting methods: setting with rotary,
switch and with tool software G2RV-SR500-AP AC100 PDF catalog.
When setting the nodes with rotary switch, setting is easy and,
node identification becomes possible for maintenance.