Protection tube diameter: screw pitch M6.
Wire length: 4m.
Core line type: K (CA).
Temperature sensing part of temperature controller.
In the application field of packaging molding machine is widely used,
Further strengthened the high cost models.
Easy to install / replace the structure.
With springs, you can use the active part (E52Z-CA1D-40) E5EN-Q3PBT-N PDF datasheet. Size: 48 x 96mm.
Type: power AC/DC24V with
E5EN-Q3PBT-N
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: position ratio control.
Auxiliary output points: 2 points.
Event entry point: 4.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: - E5EN-Q3PBT-N PDF datasheet.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms E5EN-Q3PBT-N PDF datasheet.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type. The main body: terminal type, temperature input type.
Type: control output 2 point type (power AC/DC24V).
Shell color: black.
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Furthher performance improvement E5EN-Q3PBT-N PDF catalog.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5EN-Q3PBT-N PDF catalog.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.