Sensing method: Through-beam (Emitter + Receiver).
Connection method: Pre-wired (2 m).
Sensing distance: 500 mm.
Operation mode: Dark-ON.
Model: NPN output.
Makes Mounting and Installation Simpler and Smoother.
Suitable for Applications in the Rechargeable Battery Industry. Size: M18, Shielded E5EC-QX2ASM-008 PDF datasheet.
Sensing distance: 8.0 mm.
Connection: M12 connector.
Body material: Brass
E5EC-QX2ASM-008
Thread length (overall length): 61 (75).
Output configuration: PNP.
Operation mode NC.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpieces are eliminated.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels) E5EC-QX2ASM-008 PDF datasheet.
Modular construction simplifies customization. Size: 1/4 DIN 96 × 96 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Alarm output: 3.
Control output: Voltage output(for driving SSR).
Functions: Heater burnout, No; Mounting option units, Yes.
Previous model: E5AZ-Q3 + E53-AZM E5EC-QX2ASM-008 PDF datasheet.
These Best-selling General,
purpose Temperature Controllers,
Are Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Manual output provided.
Easy setting with 11-segment displays.
New protocol called Modbus is installed in the,
models with communications.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33. Size: 96 × 96 mm.
Control type: 2-loop control.
Control mode: 2-loop standard control, 2-loop heating and cooling control,
Single-loop cascade control, Single-loop control with remote SP,
Single-loop proportional control.
Outputs(control/transfer): 4 points: Pulse voltage (2 points) and
Pulse voltage/current (2 points).
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, None; Serial communications, Yes.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using models witth CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4 E5EC-QX2ASM-008 PDF catalog. 0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation) E5EC-QX2ASM-008 PDF catalog.
DeviceNet Communications.
Data setting and monitoring can be performed without special programming.