LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Catalog Download
E2E-X10D2-M1G-Z PDF datasheet (datasheet)
Product model: E2E-X10D2-M1G-Z
Name: Standard Proximity Sensor
Brand: OMRON
Sort: PDF datasheet
File language: English
Detection mode: diffuse reflection type.
Connection mode: lead type (2 m)
Detection range: red light 100mm.
Output mode: PNP output. Sensing method: Diffuse-reflective Sensors.
Appearance: Horizontal.
Connection method: Connector (M12).
Sensing distance: 200 mm .
Functions: --.
Model: NPN output E2E-X10D2-M1G-Z PDF datasheet.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. Case color: Black E2E-X10D2-M1G-Z
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: Transfer output using control output.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, -- E2E-X10D2-M1G-Z PDF datasheet.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks E2E-X10D2-M1G-Z PDF datasheet.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: built-in SSR output.
Control output 2: built-in SSR output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E2E-X10D2-M1G-Z PDF catalog.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E2E-X10D2-M1G-Z PDF catalog.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
Related products
OMRON
Standard Proximity Sensor
E2E-X10Y1-Z 2M
OMRON Standard Proximity Sensor E2E-X10Y1-Z 2M
Appearance: M30. Sensing distance: 10 m
OMRON
Standard Proximity Sensor
E2E-X10D1S-Z 2M
OMRON Standard Proximity Sensor E2E-X10D1S-Z 2M
Appearance: M30. Sensing distance: 10 m
OMRON
Standard Proximity Sensor
E2E-X10D1-M1TGJ-U-Z 0.3M
OMRON Standard Proximity Sensor E2E-X10D1-M1TGJ-U-Z 0.3M
Appearance: M30. Sensing distance: 10 m
OMRON
Standard Proximity Sensor
E2E-X14MD2-M1G-Z
OMRON Standard Proximity Sensor E2E-X14MD2-M1G-Z
Appearance: M18. Sensing distance: 14 m