E3JK-T61 for firing type,
E3JK direct current mode: mode; shading ON,
Miniature amplifier built-in type photoelectric switchSize: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling E2A-M12KS04-WP-C2 2M PDF datasheet.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -
E2A-M12KS04-WP-C2 2M
Event input points: -.
Transfer output: output (using control output).
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure E2A-M12KS04-WP-C2 2M PDF datasheet.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E2A-M12KS04-WP-C2 2M PDF datasheet.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Detection mode: diffuse reflection type.
Connection: socket type (M12).
Detection distance: infrared 1mmmm.
Output mode: PNP output. Detection methods: the firing pattern.
Detection range: 200mm.
Usage: slender type,
Small thin space probe;
Interference prevention function with close installationSize: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostaat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E2A-M12KS04-WP-C2 2M PDF catalog.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E2A-M12KS04-WP-C2 2M PDF catalog.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.