D4N-6B72R PDF datasheet (datasheet)
Product model: D4N-6B72R
Name: Pull-reset Safety Limit Switch
Brand: OMRON
Sort: PDF datasheet
File language: English
Receptacle box: G 1/2 Conduit.
Indicator: With LED indicator (DC).
Actuator: Roller lever *1, Maintained *2.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13) D4N-6B72R PDF datasheet.
Wide standard operating temperature range:
-40°C to +100°C (standard type) D4N-6B72R
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models available for complex operations.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model D4N-6B72R PDF datasheet. ) Release key type: Special release key.
Indicator: Green.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+2NC/1NO.
Conduit opening: G1/2.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns.
Standard gold-clad contacts enable use with ordinary loads,
and microloads D4N-6B72R PDF datasheet.
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection. Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Sealed crossroller plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable llengths of 3 and 5 m available on standard models D4N-6B72R PDF catalog.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
connfirmation of operation D4N-6B72R PDF catalog.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
Related products
OMRON
Pull-reset Safety Limit Switch
D4N-1D62R
OMRON Pull-reset Safety Limit Switch D4N-1D62R
Actuator: One-way roller arm lever hori
OMRON
Pull-reset Safety Limit Switch
D4N-1A2GR
OMRON Pull-reset Safety Limit Switch D4N-1A2GR
Actuator: Adjustale roller lever, form
OMRON
Safety Limit Switch
D4N-4A31
OMRON Safety Limit Switch D4N-4A31
Actuator: Plunger. Conduit size: 1-cond
OMRON
Pull-reset Safety Limit Switch
D4N-4D2HR
OMRON Pull-reset Safety Limit Switch D4N-4D2HR
Actuator: Adjustale roller lever, form