Name: Heat/Cool Temperature Control Module.
Model: C200H-TV102.
Sensor: Platinum resistance thermometer: JPt100, Pt100.
Control output: Voltage output(transistor output used for cooling outputs).C200H CPU C200H-CPU22Supply voltage: 100 to 120 or 200 to 240 VAC (automatic voltage setting), 50/60 Hz
Operating voltage range: 85 to 132 or 170 to 264 VAC
Power consumption: 150 VA max CS1W-CLK53 PDF datasheet
CS1W-CLK53
Output capacity: 8 A, 5 VDCC500-OD I/O Unit Transistor Output 16 pts C500-OD217(3G2A5-OD217).
DC12-24V 1A.Model: C200H-OD411.
No. of points: 8 pts.
Specifications: 1A, 12 to 48 VDC.Model : C500-LDP01-V1.
Has 40 instructions (same as a C20P.) Input and output points (16 each.).CV500-MP SYSMAC BUS PC Unit PC Card Interface Board For PCMCIA 2 CS1W-CLK53 PDF datasheet. 1 Type I and II cards CV500-MP602.Model: CPM2C-8ER. Units with relay outputs only.
I/O terminal block.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: relay.Model: CPM2C-32CDTC-D. CPU Unit: Units with 32 I/O points.
2 Fujitsu connectors.
Inputs: 16 inputs.
Outputs: 16 outputs.
Input type: 24 VDC.
Output type: sinking transistor.
Internal clock: --.Size: 35mm CS1W-CLK53 PDF datasheet.
Type: 4 lines.
Lighting voltage: DC24V.
Color: red.
Large tactile buttons and uniform lighting to create a general space.
Backlight brings a uniform, elegant and pleasant lighting.
Large tactile buttons are easier to touch.
Drive rod mechanism to keep the direction of the parallel button, even if the pressure on the side of the.
Damping mechanism to ensure high impact resistance.
A slim body with a thickness of 14.6 mm. Unit type: CS1 Special I/O Units.
Product name: Isolated-type Resistance,
Thermometer Input Units (Ni508.4 Ω).
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: INi508.4.
Conversion speed (resolution):
100 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space ccompared,
with previous systems CS1W-CLK53 PDF catalog.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1W-CLK53 PDF catalog.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.