Input type: DC voltage input type.
Output type: communication; RS-485; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with KS1-ANSW90 PDF datasheet.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table
KS1-ANSW90
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviInput type: NPN/ voltage pulse input type KS1-ANSW90 PDF datasheet.
Event input terminal 5 points (HOLD, RESET, COMPENSATION) is equipped with.
External power supply DC12V80mA.
Relay contact: OUT5; OUT31c, OUT4, OUT2, OUT1: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
High speed pulse.
Measuring, increasing or decreasing pulse meter.
Action determine the color, can switch the green / Red 2 kinds of color display KS1-ANSW90 PDF datasheet.
The best choice of rotating encoder and all kinds of ON/OFF pulse signal at high speed,
Cumulative pulse input is 50kHz, phase difference pulse is 25kHz, increase or decrease of pulse is 30kHzAppearance: ADR shell.
Circuit structure and open circuit mode: single contact 1C, voltage, no voltage, DC circuit breaker.
Rated current: AC5A.
Rated frequency: 50/60Hz (switching).
Current adjustment range: time limit elements: 3-3.5-4-4.5-5-6A, 6 shunt;
Instantaneous elements: 20-30-40-50-60A-, 6 shunt.
Action time: time limit elements: 0.25-0.5-1-2-3-4-5-6-7-8-9-10-15-30-60-120,
Minimum action value, adjust the scale of movement, 300% over current, 10s plus or minus 17%;
700% over current, 16.7s plus or minus 12%; instantaneous elements: 200% over current, 50ms.
Control power supply: do not.
Rated consumption VA:6VA.
Contact capacity: closed circuit, 110V 5A L/R=0ms1000 DC220V times, 10A L/R=0ms1000 DC times;
30W (DC 110V 1A closed, L/R=25ms1000), 80VA (AC 220V 1A) cos with =0.1 1000.
Contact: AC250V, 5A, cos, DC30V, 5A, =1; Cos =1.
Automatic experiment: there.
Display: measurement display, resolution. Display resolution 9.9A the following is 0.1A, more than 1A.
Display range: 2.0A-20A, output display, trip (R phase and T phase) manual reset,
Instant manual reset type.
Excitation surge current suppression (fuzzy inference): the relative basic wave component second harmonic components of the containing rate is higher than 5%,
In the above area, the excitation surge current can be suppressed.
Quality: about 1.2kg.
External: Mount Searl N1.5.
Digital over current K2CA-H type,
Using the advanced technology of fuzzy inference to make the prrotection and coordination of digital DCR KS1-ANSW90 PDF catalog.
And automatic testing machine, so that the relay test is easy.
By using fuzzy inference, the excitation surge current is reduced.
Improve reliability by monitoring function at any timme KS1-ANSW90 PDF catalog.
With 1 sets of three-phase protection.
To save space, save wiring to make contribution.
Based on the DIN standard size, small depth is only 88.5mm.