Operation/resetting system: Time-limit operation/self,
resetting/external, resetting (see note 2).
Operation mode: 8 operation modes (selectable)(see note 3).
Terminal: 11-pin round socket.
Time-limit contact: SPDT.
Instantaneous contact: --.
Mounting: Surface mounting/track mounting; Flush mounting H5CN-YBN INSTRUCTION MANUAL.
DIN-sized (48 x 48, 45 x 75 mm) Timer with.
Digital Setting and LCD Display
H5CN-YBN
Dual power supplies for free AC/DC.
Eight operation modes selectable with one unit.
Any desired time can be set digitally within a range from 0.1,
seconds to 9,990 hrs.
Four external signal inputs.
ON/OFF indicator for control output and bar indicator for,
remaining time.
Conforms to UL, CSA, and CE marking H5CN-YBN INSTRUCTION MANUAL. Control cycle: Yearly.
Number of outputs: 4 circuits.
Mounting method: Flush mounting.
Supply voltage: 24 VDC.
Easier, More Convenient Time Switches, with,
New 4-circuit Output and Yearly Models in,
Addition to 2-circuit Weekly Models.
Independent Day Keys provide easier operation.
Temporary holiday setting function makes it easy to turn OFF,
output for holidays and non-operating days H5CN-YBN INSTRUCTION MANUAL.
Settings can be made even with the Time Switch turned OFF.
Test mode enables easy program checking.
Complies with EMC Directives, UL/CSA, and other safety standards.
Includes summer time (DST) adjustment.
Yearly models also offer automatic switching to DST.
Set value can be changed both upward and downward for speedier setting.
Integrated temperature compensation circuit helps keep,
accurate time over a wide temperature range. (See note 1.)
Includes time counter and total counter functions with alarm,
indicator. (See note 2.)
Bank function allows program swiitching by an external input H5CN-YBN Manual.
(See note 3.)
New 4-circuit output models with a compact, 72 × 72-mm DIN,
size added to the series. Count input: No-voltage.
Max. counting speed: 30 Hz ←→ 1 kHz(switchable).
Display: 7-segment LCD.
Model: Light-gray body H5CN-YBN Manual.
Eight-digits, counting range 0 to 99999999.
Dual input speed: 30 Hz ←→ 1 kHz,
(except for AC/DC multivoltage input models).